Cycle overview.

The cycle Overview window is your "cockpit". In this mask you can find all important items and reach sub-sections with only one click.

Enter the complete medication in the cycle overview. With this information, MedITEX IVF will calculate the first and last stimulation day for the DIR, the stimulation protocol, trigger shot and luteal phase support and more.

Go to the settings for changing the interface of the calendar.

 

Contents

Top section

 

The top section of the Cycle overview displays important information about this cycle, such as, type of treatment, number of embryos planned, etc.

The left section displays information contained in the Cycle details and if you click on this section, Cycle details will open.

The right section contains information that is retrieved from the cycle in course, for example, it displays, the date of the last menstrual period, the date of the triggering and the medication used, etc.

One important information about this section is the use of brackets []. Information displayed inside brackets represent what procedure took place. For example, from the image above, the treatment that was planned when creating this cycle was IVF,ICSI and, right next to it, the brackets information shows that what was planned actually happened. Another example is the Pl. sperm collection that initially, was Antegrade ejaculation but in fact, Electrostimulation was used.

 

Bottom section

The bottom section of the Overview  tab presents the calendar with the action taken on each day. Entries in the calendar are divided in 5 groups:

  1. Events: shows important events such as the first day of the last menstrual period, follicle aspiration, transfer, or clinical pregnancy. MedITEX IVF will generate this information automatically according to user entries in the corresponding cycle areas.
  2. Medication: a dynamic area where you can create an individual row for every drug used during the treatment. You can add or delete drugs from this list.
  3. Hormones: reserved fields for the values of the five most important hormones: FSH, LH, E2, PRG and HCG.
  4. Ultrasound: this row stores images of ultrasound examinations.
  5. Follicle US: in this area you can document folliculometry and other ultra sound data, including pictures of ovaries. The pictures and follicle measurements produced by special ultrasound devices can be automatically imported to MedITEX IVF via the DICOM interface, if the DICOM module has been purchased.

 

Events

EventsM.png

Right-click the respective day in the row Events to set or reposition the event.

 

The Events row shows important events such as the first day of the last menstrual period, follicle aspiration, transfer, or clinical pregnancy. MedITEX IVF will generate this information automatically according to user entries in the corresponding cycle areas.

Click here to read more about events.

 

Medication

Med.png

 

At the medication area, you can see all given drugs listed by day and dosage.

MedITEX IVF provides you with a list of all main drugs that are used in reproductive-medical treatments. Additional drugs can be individually defined in the system settings.


  • It is possible to lock single medications so they cannot be edited. In order to do that, double-click and confirm or right-click and choose Lock cell from the menu. Locked medications have a grey corner.
  • Some cells might display a red triangle on the top right corner. This indicates that it contains extra information. Move the mouse over that cell to view such data.
  • In order to edit this information, click on Medication on the left column (under Events). There you can add or delete current medications.
  • Another way of adding drugs to the list is by clicking the button .

 

In order to administrate a single medication on several days, do the following:

Method 1:

  • Select a cell;
  • Click again and enter a numeric value;
  • Click on a different cell to save the changes.
This is not a double-click. If you double-click a medication, you will be asked to lock the cell.

 

Method 2:

  • Select a cell;
  • Press CTRL-C;
  • Select another cell;
  • Press CTRL-V;

 


Method 3:

  • Enter the dosage for the desired drug in the designated date;
  • Press and hold CTRL on your keyboard;
  • Click on the last date when that drug should be administrated.

 

Method 4:

  • Select one cell;
  • Hold Shift and with the right or left arrows, select the remaining cells;
  • Press CTRL-C;
  • Select another cell to paste;
  • Press CTRL-V.

 

Pay close attention to the number of cells that were selected with this method.

 

Click here to read more about drugs.

 

Hormones

Hor.png

 

In order to enter hormone values for a patient, double-click the respective cell in the hormone area.

horm.png

 

The window Lab values will open:

horm1.png

 

From this window, you can enter all information regarding hormones for the corresponding days.

If you wish to document other hormones, you must do it from the Female lab. diagnostics. The entries for these hormones will automatically be linked to the patient's lab. diagnostics.

Add further data if needed and close the window by pressing the OK button.

Another way of entering values for hormones here in the Overview tab, is similar to the Method 1 for medications:

  • Select a cell;
  • Click again and enter a numeric value;
  • Click on a different cell to save the changes.
This is not a double-click. If you double-click a hormone cell, the editor for hormones will open.

 

You can extend the list of hormones and other laboratory parameters that are displayed in the Overview. You can edit this information at the System settings. The image below shows the Overview tab with extended lab parameters.

Click here for more information about the system settings.  

Click here for more information on how to add new parameters.

 

Ultrasound and Follicle US

Ultrasound, also referred to as US in the program, is the area in the cycle Overview where you can enter pictures of ultrasounds, folliculometric data and the endometrial thickness.

In order to add a new ultrasound picture, double-click the desired date in the Ultrasound area. The following window will open:

From this page, you can upload pictures from the ultrasound, export existing ones, add notes, etc.

 

If you double-click a cell from the Follicle US area, the following window will open:

Ultrasound pictures can also be added from this window.

 

In this window, you can document the number of follicles by size.

  • Numbers displayed to the left of the chart (22, 21,…, 10) are the sizes for the follicles;
  • Numbers in the middle of the chart are the current count of follicles of that specific size;
  • The two numbers displayed at the bottom of each ovary chart, is the sum of all follicles for that ovary;
  • The number displayed at the bottom, in the middle of both charts is the total amount of follicles counted;
  • EMT stands for Endometrium Thickness and it is measured in millimetres.

Pay really close attention to the position of the ovary charts. The left ovary is displayed on the right side and vice versa. This is to prevent mistakenly documentation, since when examining a patient, the ovaries are on the opposite side from the doctors perspective.

 

To count the number of follicles, follow this steps:

  • Move your mouse over the correct size and ovary. The row will be highlighted;
  • Left-click to add a follicle;
  • Or right-click to remove.
The middle column is updated with the current follicle count.

 

MedITEX IVF has one very important functionality. It can automatically import pictures from the ultrasound machine using DICOM. Click here to read more about this feature.

 

Click here for more information about entering US data.