Semen counter

From MedITEX - Wiki

(Difference between revisions)
Jump to: navigation, search
 
 
(10 intermediate revisions by 2 users not shown)
Line 1: Line 1:
f
+
<h2>Concentration counter</h2>
 +
<h3>Sperm counter</h3>
 +
<table border="0">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/concount.png" alt="" width="435" height="497" /><br /></td>
 +
<td>
 +
<p>&nbsp;</p>
 +
<p>&nbsp;</p>
 +
<p><strong>Predefined counting fields:</strong></p>
 +
<p>Number of sperms = 7</p>
 +
<p>&nbsp;</p>
 +
<p>The <strong>key assignments</strong> can be changed in the settings.</p>
 +
<p>&nbsp;</p>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<p>The <strong>Concentration counter </strong>can be used with a keyboard, an external number pad or a touch screen.</p>
 +
<p>A sound will identify when the counting has reached 200 entries. Then, the <strong>Concentration counter</strong> is closed and the results are automatically transferred to the <strong>Sperm calculator</strong> and can no longer be edited.</p>
 +
<p>&nbsp;</p>
 +
<h3>Configuration</h3>
 +
<table border="0">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/concount1.png" alt="" /><br /></td>
 +
<td>
 +
<ul>
 +
<li><strong>Keyboard Layout</strong>: select the desired keys for the  implementation of the sperm counting. Additionally, the position of the  selected buttons have to be set. <strong><span style="text-decoration: underline;">&nbsp;</span></strong></li>
 +
</ul>
 +
<p style="padding-left: 30px;">For example: select <strong>Number of sperms</strong> for the <strong>F1 </strong>key and set the position to number <strong>7</strong>. Now, the number <strong>7 </strong>key will be changed to <strong>F1</strong>.</p>
 +
<ul>
 +
</ul>
 +
<ul>
 +
<li><strong>Sound</strong>: select the sound that will be played when counting. Press the speaker button to test it.</li>
 +
</ul>
 +
<p>&nbsp;</p>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<p>&nbsp;</p>
 +
<table style="margin-left: auto; margin-right: auto;" border="0">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/hint48.png" alt="" width="48" height="48" /></td>
 +
<td>
 +
<p><span id="result_box" lang="en"><span class="hps">The</span>se s<span class="hps">ettings</span> <span class="hps">are stored</span> <span class="hps">individually for each user</span><span>.</span></span></p>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<p>&nbsp;</p>
 +
<h2>Motility counter</h2>
 +
<p>The <strong>Motility counter</strong> was created to provide a better and faster solution for counting the different types of motile sperms.</p>
 +
<p>It has a simple interface that allows you to count the various types of sperms with keyboard inputs. Additionally, the layout of the buttons are fully customisable and can be saved individually for each user.</p>
 +
<p>&nbsp;</p>
 +
<h3>Sperm counter</h3>
 +
<table border="0" width="781" height="152">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/motcount1.png" alt="" /></td>
 +
<td>
 +
<p><strong>Predefined counting fields:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Fast progressive motile = 7<br />&nbsp;&nbsp;&nbsp;&nbsp; Slow progressive motile = 4<br />&nbsp;&nbsp;&nbsp;&nbsp; Locally motile = 8<br />&nbsp;&nbsp;&nbsp;&nbsp; Non-linear motile = 5<br />&nbsp;&nbsp;&nbsp;&nbsp; Immotile = 9<br /><br />The key assignments can be changed in the <strong>Configuration</strong> tab.</p>
 +
<p>&nbsp;</p>
 +
<p>In the lower section of the <strong>Motility counter</strong> the current results are displayed. By default, motility is set to <strong>200 sperms</strong>. This setting can be customized in the <a href="/index.php?title=MedITEX_IVF_Settings#Semen_analysis">system settings</a>.</p>
 +
<p>&nbsp;</p>
 +
<p>The <strong>Motility counter </strong>differs during the current count in <strong>WHO A</strong>,<strong> WHO B</strong>, <strong>WHO C </strong>and<strong> WHO D</strong> and at the same time, calculates the <strong>respective percentage</strong>. This is also shown in the lower part of the counter.</p>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<p>The <strong>Motility counter </strong>can be used with a keyboard, an external number pad or a touch screen.</p>
 +
<p>A sound will identify when the counting has reached 200 entries. Then, the <strong>Motility counter</strong> is closed and the results are automatically transferred to the <strong>Sperm calculator</strong> and can no longer be edited.</p>
 +
<p>&nbsp;</p>
 +
<h3>Configuration</h3>
 +
<table border="0" width="784" height="282">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/motcount3.png" alt="" width="435" height="572" /><br /></td>
 +
<td>
 +
<ul>
 +
<li style="text-align: justify;"><strong>Keyboard Layout:</strong> select the desired keys for the implementation of the sperm counting. Additionally, the position of the selected buttons have to be set. </li>
 +
</ul>
 +
<p style="padding-left: 30px;">For example: select <strong>Immotile </strong>for the <strong>F1 </strong>key and set the position to number <strong>9</strong>. Now, number <strong>9 </strong>will be changed to <strong>F1.</strong></p>
 +
<strong>&nbsp;</strong>[[Image:Mo11.png|none|270px|thumb|left|link=http://wiki.meditex-software.com/images/Mo11.png| ]]       
 +
<ul>
 +
</ul>
 +
<ul>
 +
</ul>
 +
<ul>
 +
</ul>
 +
<ul>
 +
</ul>
 +
<ul>
 +
<li style="text-align: justify;"><strong>Sound:</strong> select the sound that will be played when counting. Press the speaker button to test it.</li>
 +
</ul>
 +
<ul>
 +
<li style="text-align: justify;"><strong>Maximum number of sperms: </strong>choose the maximum number of sperms to be counted. This setting can be customized in the <a href="/index.php?title=MedITEX_IVF_Settings#Semen_analysis">system settings</a>. After reaching this value, the <strong>Motility counter</strong> closes and transfers the values to the sperm calculator.</li>
 +
</ul>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<p><span id="result_box" lang="en"><span class="hps">&nbsp;</span><span><br /></span></span></p>
 +
<table style="margin-left: auto; margin-right: auto;" border="0">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/hint48.png" alt="" width="48" height="48" /></td>
 +
<td>
 +
<p><span id="result_box" lang="en"><span class="hps">The</span>se s<span class="hps">ettings</span> <span class="hps">are stored</span> <span class="hps">individually for each user</span><span>.</span></span></p>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<p>&nbsp;</p>
 +
<h2>Morphology counter</h2>
 +
<h3>Sperm counter</h3>
 +
<table border="0">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/morph3.png" alt="" width="435" height="685" /><br /></td>
 +
<td>
 +
<p><strong>Predefined counting fields:</strong></p>
 +
<p>Normal forms = 7</p>
 +
<p>Abnormal forms = 8</p>
 +
<p>Head defects = 4</p>
 +
<p>Neck and midpiece defects = 5</p>
 +
<p>Tail defects = 6</p>
 +
<p>Excess residual cytoplasm = 0</p>
 +
<p>&nbsp;</p>
 +
<p>In the lower section the current number of sperms counted are recorded. By default, the sperm count is set to <strong>200</strong>. This setting can be customized in the <a href="/index.php?title=MedITEX_IVF_Settings#Semen_analysis">system settings</a>.</p>
 +
<p>&nbsp;</p>
 +
<p>The <strong>Morphology counter </strong>separates sperms into <strong>normal</strong> and <strong>abnormal forms</strong>, displaying the total amount of sperms at the lower section. Once the stipulate count is reached<strong>&nbsp;</strong>, you can only update the defects of the <strong>abnormal forms</strong>.</p>
 +
<p>&nbsp;</p>
 +
<p>The percentages <strong>head defects</strong>, <strong>neck and midpiece defects</strong>, <strong>tail defects</strong> and <strong>excess redidual cytoplasm</strong> will be calculated from the number of <strong>abnormal forms</strong>.</p>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<p>The <strong>Morphology counter </strong>can be used with a keyboard, an external number pad or a touch screen.</p>
 +
<p>A sound will identify when the counting has reached 200 entries. Then, the results are transferred to the&nbsp;<strong>Sperm calculator</strong> and they can no longer be edited.</p>
 +
<p>&nbsp;</p>
 +
<h3>Configuration</h3>
 +
<table border="0">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/morph4.png" alt="" width="435" height="685" /><br /></td>
 +
<td>
 +
<ul>
 +
<li><strong>Keyboard Layout:</strong> select the desired keys for the  implementation of the sperm counting. Additionally, the position of the  selected buttons has to be set.</li>
 +
</ul>
 +
<p style="padding-left: 30px;">For example: select <strong>Excess residual cytoplasm</strong> for the number <strong>1 </strong>key, and set the position to number <strong>1</strong>. Now, number <strong>0 </strong>will be changed to <strong>1</strong>.</p>
 +
<ul>
 +
</ul>
 +
<ul>
 +
</ul>
 +
<img style="display: block; margin-left: auto; margin-right: auto;" src="/images/morph5.png" alt="" />
 +
<ul>
 +
</ul>
 +
<ul>
 +
<li><strong>Sound:</strong> select the sound that will be played when counting. Press the speaker button to test it.</li>
 +
</ul>
 +
<ul>
 +
<li><strong>Maximum number of sperms: </strong>choose the maximum number of sperms to be counted. This setting can be customized in the <a href="/index.php?title=MedITEX_IVF_Settings#Semen_analysis">system settings</a>. After reaching this value, the <strong>Morphology counter</strong> closes and transfers the values to the sperm calculator.</li>
 +
</ul>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<p>&nbsp;</p>
 +
<table style="margin-left: auto; margin-right: auto;" border="0">
 +
<tbody>
 +
<tr>
 +
<td><img src="/images/hint48.png" alt="" width="48" height="48" /></td>
 +
<td>
 +
<p><span id="result_box" lang="en"><span class="hps">The</span>se s<span class="hps">ettings</span> <span class="hps">are stored</span> <span class="hps">individually for each user</span><span>.</span></span></p>
 +
</td>
 +
</tr>
 +
</tbody>
 +
</table>
 +
<table style="float: right;" border="0">
 +
<tbody>
 +
<tr>
 +
<td style="text-align: right;"><a href="/index.php?title=MedITEX_IVF_manual">Back to the MedITEX IVF menu </a></td>
 +
<td style="text-align: right;"><a href="#top">Back to top</a></td>
 +
</tr>
 +
</tbody>
 +
</table>

Latest revision as of 12:03, 28 March 2013

Contents

Concentration counter

Sperm counter

<tbody> </tbody>
<img src="/images/concount.png" alt="" width="435" height="497" />

 

 

Predefined counting fields:

Number of sperms = 7

 

The key assignments can be changed in the settings.

 

The Concentration counter can be used with a keyboard, an external number pad or a touch screen.

A sound will identify when the counting has reached 200 entries. Then, the Concentration counter is closed and the results are automatically transferred to the Sperm calculator and can no longer be edited.

 

Configuration

<tbody> </tbody>
<img src="/images/concount1.png" alt="" />
  • Keyboard Layout: select the desired keys for the implementation of the sperm counting. Additionally, the position of the selected buttons have to be set.  

For example: select Number of sperms for the F1 key and set the position to number 7. Now, the number 7 key will be changed to F1.

  • Sound: select the sound that will be played when counting. Press the speaker button to test it.

 

 

<tbody> </tbody>
<img src="/images/hint48.png" alt="" width="48" height="48" />

These settings are stored individually for each user.

 

Motility counter

The Motility counter was created to provide a better and faster solution for counting the different types of motile sperms.

It has a simple interface that allows you to count the various types of sperms with keyboard inputs. Additionally, the layout of the buttons are fully customisable and can be saved individually for each user.

 

Sperm counter

<tbody> </tbody>
<img src="/images/motcount1.png" alt="" />

Predefined counting fields:
     Fast progressive motile = 7
     Slow progressive motile = 4
     Locally motile = 8
     Non-linear motile = 5
     Immotile = 9

The key assignments can be changed in the Configuration tab.

 

In the lower section of the Motility counter the current results are displayed. By default, motility is set to 200 sperms. This setting can be customized in the <a href="/index.php?title=MedITEX_IVF_Settings#Semen_analysis">system settings</a>.

 

The Motility counter differs during the current count in WHO A, WHO B, WHO C and WHO D and at the same time, calculates the respective percentage. This is also shown in the lower part of the counter.

The Motility counter can be used with a keyboard, an external number pad or a touch screen.

A sound will identify when the counting has reached 200 entries. Then, the Motility counter is closed and the results are automatically transferred to the Sperm calculator and can no longer be edited.

 

Configuration

<tbody> </tbody>
<img src="/images/motcount3.png" alt="" width="435" height="572" />
  • Keyboard Layout: select the desired keys for the implementation of the sperm counting. Additionally, the position of the selected buttons have to be set.

For example: select Immotile for the F1 key and set the position to number 9. Now, number 9 will be changed to F1.

 
Mo11.png
  • Sound: select the sound that will be played when counting. Press the speaker button to test it.
  • Maximum number of sperms: choose the maximum number of sperms to be counted. This setting can be customized in the <a href="/index.php?title=MedITEX_IVF_Settings#Semen_analysis">system settings</a>. After reaching this value, the Motility counter closes and transfers the values to the sperm calculator.

 

<tbody> </tbody>
<img src="/images/hint48.png" alt="" width="48" height="48" />

These settings are stored individually for each user.

 

Morphology counter

Sperm counter

<tbody> </tbody>
<img src="/images/morph3.png" alt="" width="435" height="685" />

Predefined counting fields:

Normal forms = 7

Abnormal forms = 8

Head defects = 4

Neck and midpiece defects = 5

Tail defects = 6

Excess residual cytoplasm = 0

 

In the lower section the current number of sperms counted are recorded. By default, the sperm count is set to 200. This setting can be customized in the <a href="/index.php?title=MedITEX_IVF_Settings#Semen_analysis">system settings</a>.

 

The Morphology counter separates sperms into normal and abnormal forms, displaying the total amount of sperms at the lower section. Once the stipulate count is reached , you can only update the defects of the abnormal forms.

 

The percentages head defects, neck and midpiece defects, tail defects and excess redidual cytoplasm will be calculated from the number of abnormal forms.

The Morphology counter can be used with a keyboard, an external number pad or a touch screen.

A sound will identify when the counting has reached 200 entries. Then, the results are transferred to the Sperm calculator and they can no longer be edited.

 

Configuration

<tbody> </tbody>
<img src="/images/morph4.png" alt="" width="435" height="685" />
  • Keyboard Layout: select the desired keys for the implementation of the sperm counting. Additionally, the position of the selected buttons has to be set.

For example: select Excess residual cytoplasm for the number 1 key, and set the position to number 1. Now, number 0 will be changed to 1.

<img style="display: block; margin-left: auto; margin-right: auto;" src="/images/morph5.png" alt="" />

  • Sound: select the sound that will be played when counting. Press the speaker button to test it.
  • Maximum number of sperms: choose the maximum number of sperms to be counted. This setting can be customized in the <a href="/index.php?title=MedITEX_IVF_Settings#Semen_analysis">system settings</a>. After reaching this value, the Morphology counter closes and transfers the values to the sperm calculator.

 

<tbody> </tbody>
<img src="/images/hint48.png" alt="" width="48" height="48" />

These settings are stored individually for each user.

<tbody> </tbody>
<a href="/index.php?title=MedITEX_IVF_manual">Back to the MedITEX IVF menu </a> <a href="#top">Back to top</a>