HL7 Importer
From MedITEX - Wiki
(6 intermediate revisions by one user not shown) | |||
Line 465: | Line 465: | ||
</table> | </table> | ||
<p> </p> | <p> </p> | ||
− | <h2>Message | + | <h2>Message Types</h2> |
− | <p>The messages below are examples | + | <p>The messages below are examples supported by <strong>MedITEX</strong>.</p> |
<table style="margin-left: auto; margin-right: auto;" border="0"> | <table style="margin-left: auto; margin-right: auto;" border="0"> | ||
<tbody> | <tbody> | ||
Line 476: | Line 476: | ||
</table> | </table> | ||
<p> </p> | <p> </p> | ||
− | <h3>Lab | + | <h3>Lab Values Import</h3> |
<table style="margin-left: auto; margin-right: auto;" border="0" width="100" height="383"> | <table style="margin-left: auto; margin-right: auto;" border="0" width="100" height="383"> | ||
<tbody> | <tbody> | ||
Line 499: | Line 499: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td> | + | <td>[[Image:10HL7.png|none|740px|thumb|left|link=http://wiki.meditex-software.com/images/10HL7.png|ORU-R01 fields definitions]]</td> |
</tr> | </tr> | ||
</tbody> | </tbody> | ||
</table> | </table> | ||
<p> </p> | <p> </p> | ||
+ | <table style="margin-left: auto; margin-right: auto;" border="0"> | ||
+ | <tbody> | ||
+ | <tr> | ||
+ | <td><a href="/images/Standard_ORU-R01-25.hl7"><img src="/images/plus48.png" alt="" width="48" height="48" /></a></td> | ||
+ | <td><a href="/images/Standard_ORU-R01-25.hl7">Download the file here</a>. Right-click <strong>Save link as</strong> to download.</td> | ||
+ | </tr> | ||
+ | </tbody> | ||
+ | </table> | ||
<p> </p> | <p> </p> | ||
<p> </p> | <p> </p> | ||
+ | <h3>Patient Import</h3> | ||
+ | <table style="margin-left: auto; margin-right: auto;" border="0" width="567" height="189"> | ||
+ | <tbody> | ||
+ | <tr> | ||
+ | <td> | ||
+ | <h4>ADT-A08-2.5</h4> | ||
+ | </td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td> | ||
+ | <p style="text-align: left;">MSH|^~\&|Regional MPI|MPI|Master MPI|Alpha Hospital|20060501140010||ADT^A08|3948375|P^T|2.5|</p> | ||
+ | <p style="text-align: left;">EVN|A08|20060501140008|||000338475^Author^Arthur^^^^^^Regional MPI&2.16.840.1.113883.19.201&ISO^L|20060501140008</p> | ||
+ | <p style="text-align: left;">PID|||000197245^^^National Register&2.00.123.1.123456.55.5&ISO^PN~4532^^^Careful Care Clinic&2.16.840.1.113883.19.2.400566&ISO^PI~3242346^^^Central Clinic&2.16.840.1.113883.19.2.450998&ISO^PI||Miller^Susan^^^^^L||19750103|F|||Randomroad 23a&Randomroad&23a^^Anytown^^1200^^H||001 998877^TEL^PH~001 112233^FAX^FX|001 554433^TEL^PH</p> | ||
+ | </td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="margin-left: auto; margin-right: auto;">[[Image:11HL7.png|none|519px|thumb|left|link=http://wiki.meditex-software.com/images/11HL7.png|ADT-A08 fields definitions]]</td> | ||
+ | </tr> | ||
+ | </tbody> | ||
+ | </table> | ||
<p> </p> | <p> </p> | ||
+ | <table style="margin-left: auto; margin-right: auto;" border="0"> | ||
+ | <tbody> | ||
+ | <tr> | ||
+ | <td><a href="/images/Standard_ADT_A08_25.hl7"><img src="/images/plus48.png" alt="" width="48" height="48" /></a></td> | ||
+ | <td><a href="/images/Standard_ADT_A08_25.hl7">Download the file here</a>. Right-click <strong>Save link as</strong> to download.</td> | ||
+ | </tr> | ||
+ | </tbody> | ||
+ | </table> | ||
<p> </p> | <p> </p> | ||
<table style="float: right;" border="0"> | <table style="float: right;" border="0"> |
Latest revision as of 11:51, 12 November 2015
Contents |
Scheme
Configuration
General Settings
General On/Off-Switch | Activates or deactivates the HL7-Server |
MedITEX IVF: PMI_HL7 active |
Indicates whether your IVF tool is preconfigured for the import of additional patients data and therefore provides a special interface. |
Protocol Level |
Default setting is 'Errors, Hints and Debug Information'. After the testing phase please switch to 'Only Errors' in order to reduce traffic and data storage. |
IP-Address | The IP address of the server where Importer is running. Default is 'localhost' (or 127.0.0.1). |
Number of Instances |
Defines the number of asynchronous communication queues (threads). Default is 1. |
Number of Interfaces |
Defines the number of protocols that can be interpreted. Default is 1 (HL7). |
Listen queue (max) | The maximum of entries in the listener buffer (FIFO buffer). |
Terminate wait time |
Defines the maximum delay in milliseconds to receive messages from the queue. Default is 10000 msec. |
Thread delay |
Defines the delay in milliseconds to give work time for other treads. Default is 100 msec. |
Reply ACK delay |
Defines the delay in milliseconds to finish a processed message. Default is 250 msec. |
<img src="/images/1HL7.png" alt="" width="598" height="404" /> |
COM Definitions
Tab | Item | Description |
Instances | Instance Nr. | Automatic counter |
Active | Yes or No | |
Port | The client - server communications port | |
Interfaces | Interface Nr. | Automatic counter |
Active | Yes or No | |
Protocol | Active protocol (In this version only HL7. In future versions also XML and SOAP) | |
Version | Active version | |
Libary | The name of the DLL which coummunicates with the database (Database-IN module) |
<img src="/images/2HL7.png" alt="" width="598" height="404" /> |
<img src="/images/3HL7.png" alt="" width="598" height="401" /> |
Additional Settings
Additional settings to save log files, make statistics and check the consistency of incoming data.
Saving
Item | Description |
Save Level |
Each processed message can be saved with more or less information. Default is 'Errors, Hints and Debug Information'. After the testing phase switch to 'Only Errors'. |
Save info for statistics | An additional feature to gain statistical information of the processed messages. |
Automatically load protocol file | An additional feature to display then message processing in the user interface of MexHL7Importer. The output will be according to the selection in section 'Save Level'. |
<img src="/images/4HL7.png" alt="" width="598" height="401" /> |
Patient Conditions
Items | Description |
Minimum Length of Patient Identifier | High level check whether the message details are valid to be inserted or updated in the MedITEX IVF database. If the length of the patient’s identifier is less than defined, an insert or update will be refused. |
Age Range (min/max) |
High level check whether the current age in within the defined range. |
Minimum Set of Fields | High level check whether the message details are valid to be inserted or updated in the MedITEX IVF database. If the incoming data has no values in the defined fields, an insert or update will be refused. |
<img src="/images/5HL7.png" alt="" width="598" height="401" /> |
LAB Data Conditions
Items | Description |
Use first available Patient ID | A HL7 message can provide more than one possible Patient ID because the same message can trigger several target systems wherein a Patient ought to be matched via it’s ID. |
Use Patient ID associated with IdentifierTypeCode | If provided more than one Patient ID, each of them should be followed by a so called 'Identifier Code'- which is nothing else than a second match code to decide which of the given Patient IDs is the right one for your system. |
Save Parameters as “Something else” if they can not be matched |
Laboratory parameters are divided into several parameter groups: Hormone, Serology, Clinical chemistry, Genetics, Microbiology or 'Something else'. A laboratory parameter consists of a so called short form, a long from, a unit and a value. The short form must be transmitted within the HL7 message and defined in the target system … this is the way parameters are matched. If this matching fails the parameter can be imported as “Something else” - what in each case demands a following manual correction. |
Import Notes from NTE Structure | Additional information from the examining laboratory – as a non-formatted text - can be imported in memo fields of the target system. |
Abnormal Flags | Defines whether a given parameter value is inside a normal range or outside. These flags can be used to change flags in the target system. |
Date Format |
Describes the textual form of date and time information: YYYY (year) MM (month) DD (day) HH (hour) NN (minute) SS (second). |
<img src="/images/6HL7.png" alt="" width="598" height="401" /> |
DB Access
Connection parameters to access the MedITEX IVF database:
Item | Description |
Alias | The database alias. Default is ART. |
Server |
The server address on which the Firebird server runs. Default is 'localhost' (or 127.0.0.1). |
Charset |
The character set according to your language. Ask your support for additional help. |
Client Library |
The name of the Firebird client library. Default is fbClient.dll (older versions use gds32.dll). |
Backup Start | If a backup task is defined type in the start time. This leads to a smarter and faster check whether database changings can be processed. |
Backup End | See description for point above. |
Force restart | During the processing of HL7 messages the memory usage of the HL7-Server increases continuously … not much, but it does. Therefore the time when backup is running can be used for a save restart of the HL7-Server. |
DB Access |
Strongly recommended: No access to database if backup is running should be checked! |
<img src="/images/7HL7.png" alt="" width="598" height="404" /> |
Service
(requires MexHL7Service.exe)
Item | Description |
Install service | Requires MexHL7Service.exe and provides a so called background service, with full functionality, no interface, no login necessary. If successfully installed you can see a new entry in your service panel: MexHL7 Service. |
Uninstall service | Uninstalls the MexHL7 Service. |
Start service | Starts the MexHL7 Service. |
Stop service | Stops the MexHL7 Service. |
Automatically Interface in notification area |
Provides an icon in the taskbar that indicates that the service is running and provides a GUI for configuration and statistics. This won’t work with the new Microsoft UAC technology … older operating systems like Windows XP support this feature. Try it and if you don’t see the MexHL7 Icon please uncheck this feature. |
<img src="/images/8HL7.png" alt="" /> |
Support
You can send protocol, statistic and log files to your support. Fill this formular in order to provide a smart email generator.
Item | Description |
Your Name | Type in any name you want to describe your clinic |
Your Email | Your email address |
Email Body | Any email body |
Receiver |
Default: <a href="mailto:support@critex.de">support@critex.de</a> |
<img src="/images/9HL7.png" alt="" width="598" height="404" /> |
Application
Description of the MedITEX HL7 Importer Application GUI.
To run the MexHL7Importer – after the configuration has been done – it is only necessary to click the 'Start Server' button. The screenshot bellow shows activity and data protocolling. Content depends on what has been defined in the configuration section.
<img src="/images/0GUI.png" alt="" width="765" height="990" /> |
Each pair of data (HL7 message & transformation into importable data) is – if configured – saved in a protocol file which has been named with a tamestamp. In this file you have the possibility to check when and which HL7 message data caused which import or change of MedITEX IVF data.
<img src="/images/01GUI.png" alt="" width="765" height="993" /> |
Statistical data – if configured – is automatically saved and compiled in order to provide a brief overview and a detailed table (as you can see below). For example:
Since the server was started, a total of 1373 HL7 messages were received, out of which a total of 37 errors occurred and finally 6 modifications of MedITEX IVF data have eventually been made.
<img src="/images/02GUI.png" alt="" width="765" height="530" /> |
Item | Description |
DLL Errors | Occur if any low level communication fails (tcpIP, ports , sockets, …). |
Data Errors | Occur if the consistency check of incoming data discovers missing information (a data field with no value) or invalid information (letters where only numbers were expected or violations of minimum or maximum definitions). |
Updates | Updates are only triggered if the associated patient already exists in the MedITEX IVF patient table. |
Edits | Edits are triggered if the associated patient exists in the MedITEX IVF buffer table. |
Inserts | Inserts into the so called buffer table are processed if the associated patient could not be found in both tables (patient table and buffer table). |
Modifies | Whether triggered 'Updates' or 'Edits' are finally processed is decided dependent of the data field values. If no modifications of data are found no change of the database is performed. |
<img src="/images/03GUI.png" alt="" width="765" height="990" /> |
Message Types
The messages below are examples supported by MedITEX.
<img src="/images/hint48.png" alt="" width="48" height="48" /> | Please note that event typs such as, R01 and A08, are ignored. MedITEX will decide what to do with the message. |
Lab Values Import
ORU-R01-2.5 |
MSH|^~\&|LABOR1|14|LAB|MedITEX|20150109122547||ORU^R01|16216545|P|2.5||||||8859/1 PID||3333|096733119^^^GLIMS||Miller^Susan||19801122000000|F|||Randomroad 10^^Anytown^NY^12345 ORC|NW||10-00740090S^14||CM||^^^20150109112946|||||LOFT1^Loft^John^^^^Dr^^^^GLIMS|||20150109000000 OBR|1||10-00740090S^14||||20150109071000|||||||20150109112946||IVF-Clinic^^^^^^^^MedITEX||||User1||20150109000000|||M||| OBX|1|SN|lh^LH^GLIMS||8.7|U/l||N|||F|||||| NTE|1|L|2.4 - 12.6 Follicularphase\.br\14.0 - 95.6 Ovulationspeak\.br\1.0 - 11.4 Lutealphase\.br\7.7 - 58.5 Postmenopause OBX|3|SN|prog^Progesteron^GLIMS||1.7|nmol/l||N|||F|||||| NTE|1|L|0.6 - 4.7 Follicularphase\.br\2.4 - 9.4 Ovulationspeak\.br\5.3 - 86.0 Lutealphase\.br\0.3 - 2.5 Postmenopause OBX|5|SN|estra^Oestradiol (E2)^GLIMS||166.8|pmol/l||N|||F|||||| NTE|1|L|46 - 607 Follicularphase\.br\315 - 1828 Ovulationspeak\.br\161 - 774 Lutealphase\.br\<18.4 - 201 Postmenopause |
<a href="/images/Standard_ORU-R01-25.hl7"><img src="/images/plus48.png" alt="" width="48" height="48" /></a> | <a href="/images/Standard_ORU-R01-25.hl7">Download the file here</a>. Right-click Save link as to download. |
Patient Import
ADT-A08-2.5 |
MSH|^~\&|Regional MPI|MPI|Master MPI|Alpha Hospital|20060501140010||ADT^A08|3948375|P^T|2.5| EVN|A08|20060501140008|||000338475^Author^Arthur^^^^^^Regional MPI&2.16.840.1.113883.19.201&ISO^L|20060501140008 PID|||000197245^^^National Register&2.00.123.1.123456.55.5&ISO^PN~4532^^^Careful Care Clinic&2.16.840.1.113883.19.2.400566&ISO^PI~3242346^^^Central Clinic&2.16.840.1.113883.19.2.450998&ISO^PI||Miller^Susan^^^^^L||19750103|F|||Randomroad 23a&Randomroad&23a^^Anytown^^1200^^H||001 998877^TEL^PH~001 112233^FAX^FX|001 554433^TEL^PH |
<a href="/images/Standard_ADT_A08_25.hl7"><img src="/images/plus48.png" alt="" width="48" height="48" /></a> | <a href="/images/Standard_ADT_A08_25.hl7">Download the file here</a>. Right-click Save link as to download. |
<a href="/index.php?title=Import_and_Export_tools">Back to Import and Export tools</a> | <a href="#top">Back to top</a> |